Delivery terms and costs
Security policy
Do you have questions? We are available to help!
HAIER Super Aqua monoblock heat pumps are pumps dedicated to heating central heating and DHW, i.e. central heating and domestic hot water.
A heat pump is a device that obtains thermal energy from the air. This process is independent of the season, both in summer and winter we are able to heat the house and domestic water using Haier heat pump.
Super Aqua series heat pumps are able to work with various heat consumers in the building - these can be both radiators and surface heating (such as the popular underfloor heating) and fan coil units.
HAIER heat pump kit:
The heat pump kit includes:
heat pump outdoor unit
controller
heat pump control module
HAIER heat pump heats the building comprehensively:
The modern solution of HAIER heat pumps are able to work with various heat consumers. The best receiver will be underfloor heating, which will guarantee low electricity consumption - that is, high efficiency of the device.
What is important, especially for modernized facilities, is that the pump will cope well with traditional radiators. Nothing stands in the way of the pump also working with fan coils, acting similarly to an air conditioner, only instead of the refrigerant, water is supplied, which gives off energy to the air in the rooms.
HAIER Super Aqua series monobloc heat pumps are characterized by quiet operation at 59db(A) at a distance of 1m from the unit.
Compressors in the inverter version (which are already quiet by design) are covered with a dedicated material designed to eliminate noise.
Another element that contributes to the reduction of loudness is the special shape of the fan, whose task is to reduce vibrations.
HAIER heat pumps are equipped with a sensor that prevents freezing in harsh weather conditions. It detects temperatures below 3 degrees and starts the pump to avoid damaging the system.
The pump is also equipped with a water flow sensor, which prevents freezing in cooling mode when the flow is minimal.
HAIER heat pumps have a very intuitive and easy-to-read wall (wired) controller, which is an integral part of the heat pump kit.
The pump controller allows you to select the mode of operation, set the schedule of the device, as well as display errors - if any.
Thanks to the DC inverter compressor, the Haier heat pump is, on the one hand, a very quiet device, on the other hand, very economical.
Mitsubishi double inverter compressor allows operation at different frequencies, the heat pump that can modulate (operate at 3kW, for example) consumes less electricity.
HAIER heat pumps are able to provide water with an outlet temperature of 5 to 55°C, which makes it possible to adapt to the prevailing conditions in the building.
The aforementioned 55°C outlet temperature is achievable even at -20°C prevailing outside.
Super Aqua monoblocs are environmentally friendly pumps that are able to produce heat energy all year round.
Thanks to Haier pumps, we have the possibility to heat the building in the cold and use it in cooling mode in the summer (via fan coils or underfloor heating).
HAIER heat pumps operate in A+++/A++ class (for a 5kw pump), which translates into very low electricity consumption.
Haier has equipped the heat pumps with environmentally friendly R32 refrigerant with reduced impact on the greenhouse effect, as well as higher efficiency and lower energy consumption.
Technical data:
Power supply f/V/Hz 1/220-240/50/60
Capacity (heating.)*1 [kW] 5.0
Power consumption (heating.)*1 [kW] 1.64
Efficiency (heating)*2 [kW] 5.0
Power consumption (grz.)*2 [kW] 0.99
Capacity (cool.)*3 [kW] 5.0
Power consumption (heating)*3 [kW] 1.0
Capacity (cooling)*4 [kW] 5.0
Power consumption (heating)*4 [kW] 1.56
COP *1 3.05
COP *2 5.05
EER *3 5.0
EER *4 3.2
Sound power level [dB(A)] 59
Water flow [l/min.] 14.3
Dimensions (W/H/D) [mm] 920/760/372
Weight [kg] 69
Refrigerant R32
Refrigerant fill [kg] 1.05
Diameter of the water pipeline inlet/outlet. [inch] 3/4
Operating temp. (cool) [°C] 10~46
Operating temp. (heating) [°C] -20~35
Discharge water temp. (cooling) [°C] 5~20
Outlet (heating) water temp. [°C] 20~55
YR-E27 wired controller
PCB, hot water ATW-A01
*1 Cooling: water at inlet/outlet 12/7°C, ambient temperature 35°CDB.
*2 Cooling: water at inlet/outlet 23/18°C, ambient temperature 35°CDB.
*3 Heating: water at inlet/outlet 40/45°C, ambient temperature 7/6°CDB.
*4 Heating: water at inlet/outlet 30/35°C, ambient temperature 7/6°CDB.
All parameters are tested in a semi-anechoic room. The above data are subject to update. DHW only with ATW-A01